A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters: • Resistance of the 2400-volt winding Ri=0.75 ohm
Resistance of the 240-volt winding R=0.0075 ohm
Leakage reactance of the 2400-volt winding X:=1 ohm
Leakage reactance of the 240-volt winding X2=0.01 ohm
Core loss resistance on the 2400 side Rc=733.5 ohms
Magnetizing reactance on the 2400 side X=4890 ohms
a. Draw the equivalent circuit referred to the high voltage side and referred to the low- voltage side. Label the impedances numerically.
b. The transformer is used as a step-down transformer at the load end of a feeder having impedance of (0.5+j2.0) ohms. Determine the voltage V. at the ending end of the feeder when the transformer delivers rated load at rated secondary voltage and 0.8 laggin power factor. Neglect the "exciting current" l. of the transformer (this is the current into the parallel Rc/jXm combination), which is another way of saying that you should use what we called in class the "approximate circuit #2).

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The higher the astm grain-size number, the coarser the grain is. a)-true b)-false
Answers: 3
question
Engineering, 04.07.2019 18:10
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
You know the right answer?
A single phase, 50-KVA, 2400-240-volt, 60 Hz distribution transformer has the following parameters:...
Questions
question
Mathematics, 02.06.2021 20:30
question
Mathematics, 02.06.2021 20:30
question
Mathematics, 02.06.2021 20:30
question
Mathematics, 02.06.2021 20:30
question
Mathematics, 02.06.2021 20:30
question
Mathematics, 02.06.2021 20:30
Questions on the website: 13722362