subject
Engineering, 28.10.2020 16:50 tory74

Convection, Conduction, and Overall U. A gas at 450 K is flowing inside a 2-in. steel pipe, schedule 40. The pipe is insulated with 51 mm of lagging having a mean k = 0.0623 W/m · K. The convective heat-transfer coefficient of the gas inside the pipe is 30.7 W/m2 · K and the convective coefficient on the outside of the lagging is 10.8. The air is at a temperature of 300 K. Calculate the heat loss per unit length of 1 m of pipe using resistances. Repeat, using the overall U0 based on the outside area A0.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 19:10
A)-explain briefly the importance of standards in engineering design. b)- what is patent? c)-explain the relationship between these standards: b.s. and b.s.en d)- in engineering design concepts, types of loads and how they act are important factors. explain.
Answers: 3
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
question
Engineering, 06.07.2019 04:10
An inventor claims to have developed a reversed heat engine (ie. a heat pump) which is able to deliver 10 kj heat into the room at 20°c from outside ambient temperature of -10°c by consuming only 2 kj electricity in winter. this claim is a)-impossible b)-possible only if the heat pump is ideal c)-practically possible d)-unable to be assessed as it depends on the working fluid used in the heat pump.
Answers: 2
You know the right answer?
Convection, Conduction, and Overall U. A gas at 450 K is flowing inside a 2-in. steel pipe, schedule...
Questions
question
Mathematics, 10.02.2022 21:20
Questions on the website: 13722363