subject
Engineering, 10.11.2020 01:00 brendaesme

A block is sliding down an incline of 60 degrees as shown in the figure below. The coefficient of friction, μ , of the surface of the incline plane is 0.3. The frictional force is = μ where is the normal force. The weight of the block is W. Assume the acceleration due to gravity is 9.8 m/ 2 (a) Provide the expression for the component for the Weight force in the direction along the incline plane.
(b) Provide the expression for the component for the Weight force in the direction perpendicular to the incline plane.
(c) Provide the expression for the normal force in terms of W.
(d)
Provide the expression for in terms of W.
(e) Provide the equation for the sum of the forces in the direction along the incline plane (include appropriate signs).
(f) Provide the equation for the sum of the forces in the direction perpendicular to the incline plane (include appropriate signs).
(g) What is the value for acceleration of the block along the incline plane?
(h) How far (in meters) will the block slide in 10 seconds if it is released from rest?


A block is sliding down an incline of 60 degrees as shown in the figure below. The coefficient of f

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 03.07.2019 15:10
Ahouse has the following electrical appliance usage (1) single 40w lamp used for 4 hours per day (2) single 60w fan used for 12 hours per day (3) single 200w refrigerator that runs 24 hours per day with compressor run 12 hours and off 12 hours find the solar power inverter size in watt with correction factor of 1.25.
Answers: 1
question
Engineering, 04.07.2019 18:10
The mass flow rate of the fluid remains constant in all steady flow process. a)- true b)- false
Answers: 1
question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
You know the right answer?
A block is sliding down an incline of 60 degrees as shown in the figure below. The coefficient of fr...
Questions
question
Mathematics, 03.12.2020 19:20
question
Mathematics, 03.12.2020 19:20
question
Mathematics, 03.12.2020 19:20
question
History, 03.12.2020 19:20
question
English, 03.12.2020 19:20
question
Mathematics, 03.12.2020 19:20
Questions on the website: 13722363