subject
Engineering, 16.11.2020 18:10 babyskitt

The water in a soil flows from Point K to Point L, a distance of 250 ft. Point K is at elevation 543 ft and Point L is at elevation 461 ft. Piezometers have been installed at both points, and their water levels are 23 ft and 74 ft, respectively, above the points. Compute the average hydraulic gradient between these two points.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 18:20
Steam enters a converging nozzle at 3.0 mpa and 500°c with a at 1.8 mpa. for a nozzle exit area of 32 cm2, determine the exit velocity, mass flow rate, and exit mach number if the nozzle: negligible velocity, and it exits (a) is isentropic (b) has an efficiency of 94 percent
Answers: 2
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
The water in a soil flows from Point K to Point L, a distance of 250 ft. Point K is at elevation 543...
Questions
question
Mathematics, 03.04.2020 00:55
question
Mathematics, 03.04.2020 00:55
question
Mathematics, 03.04.2020 00:56
question
Spanish, 03.04.2020 00:56
question
Advanced Placement (AP), 03.04.2020 00:56
question
Mathematics, 03.04.2020 00:56
Questions on the website: 13722360