subject
Engineering, 09.04.2021 02:30 dborges4070

You are given the following material properties for a stiff, particulate filler material (aggregate) and a lightweight (but not so stiff) matrix (binder). E_agg= 30GPa, E_matrix =1.55 GPa, p_agg= 2400 kg/m3, P_matrix=1050 kg/m3
For your particular application, it is important to have a stiff material but also one that is lightweight. In fact, the optimum stiffness to unit weight ratio is 11.1 MPa/kg/m^3. Determine the optimum volume fractions (0 to 1) for the matrix and the particulate if the composite stiffness behaves according to the following models:
a) series
b) parallel
c) Hirsch with x = 0.2, x = 0.4, x = 0.8

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
question
Engineering, 06.07.2019 03:20
Areaction-bonded silicon nitride ceramic has a strength of 250 mpa and a fracture toughness of 3.4 mpa(m)^1/2, what is the largest-sized internal flaw that this material can support without fracturing? (use y -1 in the fracture-toughness equation.)
Answers: 3
You know the right answer?
You are given the following material properties for a stiff, particulate filler material (aggregate)...
Questions
question
Mathematics, 14.12.2020 19:20
question
Mathematics, 14.12.2020 19:20
question
English, 14.12.2020 19:20
question
Mathematics, 14.12.2020 19:20
Questions on the website: 13722362