Engineering, 13.05.2021 14:00 leannadoughty06

1. The WAB Bank decided to open up two new drive-through teller windows outside its main office building in Sariaya, Quezon. The bank is not sure that it needs both windows open all day so it has decided to conduct work sampling study to determine the proportion of time the two tellers are idle between the hours of 10:00AM to 11:30 AM and 1:00 PM to 3:00 PM. The work sampling study was conducted at random over a five-day period and the following observations were recorded: (table on the file) 2. Bank management wants the study to be +/- 5% accurate with a 95% confidence level. How many additional sample observations should be taken? (refer to table)

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:20
Inspection for bearing condition will include: (clo4) a)-color b)-smell c)-size d)-none of the above
Answers: 1
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
1. The WAB Bank decided to open up two new drive-through teller windows outside its main office buil...
Questions
question
Mathematics, 20.09.2020 08:01
question
Mathematics, 20.09.2020 08:01
question
Mathematics, 20.09.2020 08:01
question
Mathematics, 20.09.2020 08:01
question
Mathematics, 20.09.2020 08:01
Questions on the website: 13722363