subject
Engineering, 22.05.2021 04:30 yolo1430

An OSHA inspection follows a standard process, consisting of three phases. What are these phases? Select the 3 answer options that apply.

Opening conference

Citation period

Walkthrough

Closing conference

Interviews with each worker

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:20
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
question
Engineering, 06.07.2019 03:20
1kg of water contained in a piston-cylinder assembly undergoes two processes in series from an initial state where the pressure is 3.0 bar and the temperature is 150°c process 1-2: the water is compressed isothermally to a volume of 0.25 m^3 with 120 kj of work being done to the system. process 2-3: the water is heated at constant volume to a final pressure of 10 bar. a. find the change in internal energy for the system. b. calculate the amount of heat transferred, in kj. c. sketch both processes on a t-v diagram. (196.33 kj/kg, 76.33 kj)
Answers: 1
question
Engineering, 06.07.2019 04:10
Consider a power plant with water as the working fluid that operates on an ideal rankine cycle. it has a net power output of 45mw. superheated steam enters the turbine at 7mpa and 500°c (h=3411.4 kj/kg; s=6.8 kj/kg k) and is cooled in the condenser at a pressure of 10 kpa by running cooling water from a lake through the tubes of the condenser at a rate of 2000 kg/s. (a) show the cycle on a t-s diagram (a right schematic is fine - you do not need to calculate the temperatures at each point); (b)-determine the work done by the turbine and the pump in kj/kg; (c)-the mass flow rate of water used by the power plant; (d)-the thermal efficiency of the cycle; (e)-the temperature rise of the cooling water. assume the cooling water is incompressible with cp 4.18 kj/kg°c.
Answers: 3
question
Engineering, 06.07.2019 04:10
Ir at sea level and 30°c and 50% relative humidity flows at a rate of 1 kg/s through a cooling coil that has an apparatus dewpoint of 10°c. the air leaves the coil at 15°c. determine the following: 3.1)- relative humidity of the air leaving the coil; 3.2)- moisture content of the air leaving the coil; 3.3)- sensible heat factor; 3.4)- total heat transfer rate; 3.5)- sensible heat transfer rate 3.6)- latent heat transfer rate
Answers: 1
You know the right answer?
An OSHA inspection follows a standard process, consisting of three phases. What are these phases? S...
Questions
question
Business, 24.07.2019 14:30
Questions on the website: 13722363