Consider three monitoring wells, each located at the vertex of an equilateral triangle. The distance between any pair of wells is 300 m. The head at each well, referenced to some common datum, is as follows: well 1, 100 m; well 2, 100.3 m; well 3, 100.3 m. Sketch the well field and find the magnitude and direction of the hydraulic gradient.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 05.07.2019 04:30
Technician a says that in a worm gear steering system, most excessive steering free play is usually found in the gearbox. technician b says that in a rack-and-pinion steering system, excessive free play can be found in the bushings. who is correct?
Answers: 2
question
Engineering, 06.07.2019 04:10
Aheat pump using refrigerant-134a heats a house by using underground water at 8°c as the heat source. the house is losing heat at a rate of 60,000 kj/h. the refrigerant enters the compressor at 280 kpa and 0°c, and it leaves at 1 mpa and 60°c. the refrigerant exits the condenser at 30°c. determine: (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump
Answers: 2
question
Engineering, 06.07.2019 04:20
Steam in a heating system flows through tubes whose outer radius is 2.5 cm and whose walls are maintained at a temperature of 180 °c . circular aluminum alloy 2024-t6 fins ( k= 186 wm. k) of outer radius 3 cm and constant thickness 1 mm are attached to the tube. the space between the fins is 3 mm and thus there are 250 fins per meter of tube length. heat is transferred to the surrounding air at too-25 °c, with a heat transfer coefficient of 40 w/m2. k. manufacturer a claims that this system is rated at 3.5 kw per meter of tube length. if the fins are an integral part of the steam tube, find the heat transfer rate in kw for a 1-m length of tube. is manufacturer a's claim valid? compare the heat transfer rate from 1 meter of tube length if there are no fins.
Answers: 3