subject
Engineering, 28.05.2021 16:20 dokithefursona

An adsorption column with a diameter of 2.0 cm and a bed height of 5.8 cm was used to isolate the digestive enzyme, trypsin. The concentration of trypsin in the feed was 0.190 mg/mL. The flow rate of the feed was 0.109 cm3/sec. The void volume in the bed was 0.35. The bulk density of the adsorbent (in its hydrated state in the bed) is 1.03 g/cm3. The volumes eluted at breakthrough (0.1yF) and exhaustion (0.9yF) were 150 and 450 cm3, respectively. (Recall that volume eluted and time can be related through the volumetric flow rate.) (a) Estimate the loading of trypsin on the adsorbent (mg/g) at breakthrough and at exhaustion for the feed concentration given.
(b) If you choose a breakthrough concentration of 0.01 mg/mL at 200 cm3, what is the fraction of adsorbent bed utilized?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Thermal stresses are developed in a metal when its a) initial temperature is changed b) final temperature is changed c) density is changed d) thermal deformation is prevented e) expansion is prevented f) contraction is prevented
Answers: 2
question
Engineering, 04.07.2019 18:20
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?
Answers: 2
question
Engineering, 04.07.2019 19:10
An electric kettle is made out of stainless steel, weighs two pounds (when empty) and is equipped with a heating element that consumes 2 kw of electricity. assuming that the water and the kettle are at the same uniform temperature at any moment of time, calculate the shortest possible time to bring 2 quarts of water from room temperature to the onset of boiling
Answers: 2
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
You know the right answer?
An adsorption column with a diameter of 2.0 cm and a bed height of 5.8 cm was used to isolate the di...
Questions
question
English, 08.12.2020 16:40
question
Mathematics, 08.12.2020 16:40
question
Mathematics, 08.12.2020 16:40
question
Mathematics, 08.12.2020 16:40
Questions on the website: 13722363