Time left 0:42:59 Two balanced three phase loads are connected in parallel, the loads are L,=30 kVA at 0.9 pf lag, and L2= 40 kW at 0.795 pf lag.
The loads are fed from a distribution line with an impedance of 0.1+j0.1 /0. The line to neutral voltage at the load end is 288 V
and zero phase shift, the phase current of the second load in A (if it is A-connected) is;
O A. 26.73-j20.39
O B. 33.35-14.30
O C. 100.04-112.89
O D. 80.19-361.18
O E 46.30-135.32
O F.57.76-17.44
O G. None
Two balanced three phase loads are connected in parallel, the loads are L1=30 KVA at 0.9 pf lag, and L2= 40 kW at 0.795 pf lag.
The loads are fed from a distribution line with an impedance of 0.1+j0.1 92/0. The line to neutral voltage at the load end is 288 V
and zero phase shift, the capacitance of A-connected capacitor bank that connected parallel to the loads to improve the power factor
to unity in uF is; (f=60 Hz)
A 154.92
OB. 51.64
OC 464.76
OD. 1394.28
O E. None​

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 23:20
Two technicians are discussing the intake air temperature (iat) sensor. technician a says that the computer uses the iat sensor as a backup to the engine coolant temperature (ect) sensor. technician b says that the powertrain control module (pcm) will subtract the calculated amount of fuel if the air measures hot. who is correct
Answers: 3
question
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?