subject
Engineering, 23.07.2021 16:50 hdkdkdbx

For an applied transformer with a primary winding of 220, a secondary winding of 113 turns, a core of 45 cm2 cross-section and a rated supply voltage of 220 V, frequency f = 50 Hz, number system Core style K = 1,2. one. Calculated from the sensor in the core transformer.
NS. Calculate the rated capacity of the transformer application.
C. Calculating no-load voltage and current levels.
NS. If the power point is reduced by 7% from the voltage level; voltage scortation feature.
e. If use the core machine variable on random form; powerpress same as the host variable on; compare the capacity of the random transformer with the capacity of the transformer application.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
question
Engineering, 04.07.2019 19:10
Agas is compressed from vi 0.3 m, p 1 bar to of v2 0.1 m3, p2--3 bar. pressure and volume are related linearly during the process. for the gas, find the work, in kj.
Answers: 2
question
Engineering, 06.07.2019 03:10
Different between right hand turning tool and left hand turning tool ?
Answers: 1
question
Engineering, 06.07.2019 03:30
The catalogue for a refrigerant 22, four-cylinder, hermetic compressor operating at 29 r/s. a condensing temperature of 40°c and an evaporating temperature of -4°c shows a refrigeration capacity of 115 kw. at this operating point, the motor (its efficiency is 90 percent) draws 34.5 kw. the bore of the cylinders is 87 mm and the piston stroke is 70 mm. the performance data are based on 8°c of sub-cooling of the liquid leaving the condenser. compute (a) the actual volumetric efficiency and (b) the compression efficiency.
Answers: 2
You know the right answer?
For an applied transformer with a primary winding of 220, a secondary winding of 113 turns, a core o...
Questions
question
Mathematics, 07.04.2020 01:10
question
Mathematics, 07.04.2020 01:11
question
History, 07.04.2020 01:11
Questions on the website: 13722361