subject
Engineering, 19.10.2021 01:00 mauifrifer3986

For the slab system of Storage warehouse with heavy equipment that shown in the plan below, use ACL code Load combinations table and following available data.
Find out the
1. Ultimate area load ( w ) kN/m2 on slab 1
2. Ultimate Linear load ( Wu) kN/m on Beaml and Beam 2
3- Ultimate Point load (Pe) kN on Col. l. Col.2 and Col. 3
Available data for Dead Load calculation
Slab thickness = 0.21m
Assume Reinforced concrete density = 23.8 kN/m
*
Superimposed dead load = 1.2 kN/
m2
Use Table 1.1 for assuming Live load on the slab with respect to its occupation
800 m
600 m
Coll
Beam 1
Slable
1 00 m
Col
Col
900 m
Beam
(1.21 m
1.6 mm
110 m


For the slab system of Storage warehouse with heavy equipment that shown in the plan

below, use A

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The filament of an incandescent lamp has a temperature of 2000k. calculate the fraction of radiation emitted in the visible light band if the filament is approximated as blackbody
Answers: 2
question
Engineering, 04.07.2019 18:10
Calculate the bore of a cylinder that has a stroke of 18 inches and an extension time of 6 seconds at a flow rate of 4 gal/min.
Answers: 3
question
Engineering, 04.07.2019 18:20
An open feedwater heater operates at steady state with liquid entering at inlet 1 with t? = 40°c and pl = 1 .2 mpa. water vapor att2-200°c and p2 = 1.2 mpa enters at inlet 2. saturated liquid water exits with a pressure of pa 1.2 mpa. neglect heat transfer with the surroundings and all kinetic and potential energy effects, determine the mass flow rate of steam at inlet 2 if the mass flow rate of liquid water at inlet 1 is given as 2 kg/s.
Answers: 3
question
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
You know the right answer?
For the slab system of Storage warehouse with heavy equipment that shown in the plan below, use AC...
Questions
question
Biology, 29.06.2019 01:30
question
Social Studies, 29.06.2019 01:30
Questions on the website: 13722360