subject
Engineering, 17.02.2022 08:40 aaron0828

Help me!! Within the processes of a power plant, combustion product gases are available at 430 ºC. It is required to take advantage of the heat of these gases and it is proposed to size an economizer to heat pressurized water from 70ºC to 180ºC.
It is known that there is 8 kg/s of water with Cp=4260 J/kg. K. The gases have a flow of 30 kg/s and Cp=1100 J/kg. K. Calculate:
a) the heat that can be transferred from the gases to the water, in kW.
b) the outlet temperature of the combustion gases, in ºC.
b) the average logarithmic difference of temperatures of the economizer, in ºC.
c) the required heat transfer area in m2, for a counterflow configuration if the overall heat transfer coefficient is 60 W/m2 K.
d) If you plan to use a coil of tubes 4 m long and 15 cm in diameter, calculate the number of tubes needed for the economizer.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 14:10
If the thermal strain developed in polyimide film during deposition is given as 0.0044. assume room temperature is kept at 17.3 c, and thermal coefficient of expansion for the film and the substrate are 54 x 10^-6c^-1 and 3.3 x 10^-6c^-1respectively. calculate the deposition temperature.
Answers: 3
question
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 19:10
What is the major difference between thermoplastics and thermosetting plastics from the polymerization structure point of view?
Answers: 2
You know the right answer?
Help me!! Within the processes of a power plant, combustion product gases are available at 430 ºC....
Questions
question
History, 02.09.2019 04:00
question
English, 02.09.2019 04:00
question
Mathematics, 02.09.2019 04:00
question
Mathematics, 02.09.2019 04:00
Questions on the website: 13722367