subject
Engineering, 16.01.2020 04:31 wxvvyyyy

Consider one more time the following contract specification for the static method smooth. smooths a given (@code sequence < integer > }. @param s1 the sequence to smooth @param s2 the resulting sequence @replaces s2 @requires |s1| > = 1 @ensures < pre > |s2| = |s1| - 1 and for all i, j: integer, a, b: string of integer where (s1 = a < i > < j > b) (there exists c, d: string of integer) (|c| = |a| and s2 = c < (i + j)/2 > d)} < /pre > /public static void smooth (sequence < integer > s1, sequence < integer > s2) {. answer the following questions. redesign the method so that it is a function that returns the new (smoothed) sequence instead of replacing a parameter. you need to modify the method header and update the formal contract to reflect the changes. provide two distinct implementations of the newly designed smooth method, one recursive and one iterative (i. e., not using recursion). while you may use method entry, do not use any other method that is introduced in the enhanced interface sequence. among the methods still permitted for your use arc all those inherited by or introduced in sequencekernel, including add, remove, and length.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
If a particle moves along a path such that r : (3 sin t) m and ? : 2t rad, where t is in seconds. what is the particle's acceleration in m/s in 4 seconds? a)- 16.43 b)- 16.29 c)- 15.21 d)- 13.79
Answers: 1
question
Engineering, 04.07.2019 18:10
The drive force for diffusion is 7 fick's first law can be used to solve the non-steady state diffusion. a)-true b)-false
Answers: 1
question
Engineering, 04.07.2019 19:10
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces.a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
question
Engineering, 04.07.2019 19:10
Plan an experiment to measure the surface tension of a liquid similar to water. if necessary, review the ncfmf video surface tension for ideas. which method would be most suitable for use in an undergraduate laboratory? what experimental precision could be expected?
Answers: 2
You know the right answer?
Consider one more time the following contract specification for the static method smooth. smooths a...
Questions
question
Mathematics, 15.04.2020 04:31
question
Biology, 15.04.2020 04:31
Questions on the website: 13722361