subject
Engineering, 19.02.2020 23:13 heyhowdy

A stainless steel (AISI 304) tube used to transport a chilled pharmaceutical has an inner diameter of 36 mm and a wall thickness of 2 mm. the pharmaceutical and ambient air are at temperatures of 6degree C and 23 degree C, respectively, while the corresponding inner and outer convection coefficients are 400 W/m^2 middot K and 6 W/m^2 middot K, respectively. a. What is the heat gain per unit tube length? b. What is the heat gain per unit length if a 10-mm-thick layer of calcium silicate insulation (k_ins = 0.050 W/m middot K) is applied to the tube?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Journeyman training is usually related (clo2) a)-to specific tasks b)-to cost analysis of maintenance task c)-to control process to ensure quality d)-to installation of machinery
Answers: 2
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:20
Areaction-bonded silicon nitride ceramic has a strength of 250 mpa and a fracture toughness of 3.4 mpa(m)^1/2, what is the largest-sized internal flaw that this material can support without fracturing? (use y -1 in the fracture-toughness equation.)
Answers: 3
question
Engineering, 06.07.2019 04:10
Cold water (cp=4180j/kg k) leadıng to a shower enters a thin-walled double-pipe heat transfer at 15c at a rate of 0.25kg/s and is heated to 45c by hot water (cp=4190j/kg k) that enters at 100c at the rate of 3kg/s. if the overall heat transfer coefficient is 950w /m2 k , determıne the rate of heat transfer and the heat transfer surface area of the heat exchanger using e - ntu method
Answers: 1
You know the right answer?
A stainless steel (AISI 304) tube used to transport a chilled pharmaceutical has an inner diameter o...
Questions
Questions on the website: 13722360