subject
Engineering, 05.05.2021 17:00 reearamrup27

Garden City is finalizing the design of an activated sludge WWTP and has the following design information available. Design Flowrate = 4 MGD; Plant Water Temperature = 22°C. A) Design the Activated Sludge Tank for the WWTP. Using the design information below, determine: (a) the substrate, S, concentration in mg/L in the activated sludge tank, (b) the detention time of the tank in hours, and (c) the volume of the tank in m3 . Again, Q = 4 MGD.
B) Design the Activated Sludge Tank for the WWTP (continued). Using the design information given in the previous problem, calculate the: (a) cell wasting (Qw) and (b) cell recycling (Qr) rates in MGD for the tank. (c) What is the value of the F:M ratio in mg BOD5/mg MLVSS-day? Is this value acceptable? Use the equations below to calculate cell wasting and recycling rates: Qr/Q = X/(Xr-X) and Qw = (VX)/(θCXr)
Activated Sludge Tank Design Information:
MCRT (c) Ks | 10 days 100 mg/L 0.5 0.05/day 2.5/day Xo, Xe Negligible | 3,500 mg/L MLVSS 10,000 mg/L MLVSS Influent BOD5 | 220 mg/L Y Xr kd Um

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 19:20
In the winter, in order to keep the classroom steadily at 68 f before 10 pm, heating with an average rate of 42,000 btu/hr is provided. assume the outdoor temperature maintains at 32°f, determine the electrical power (kw) required to (a) operate a reversible heat pump (b) operate a real heat pump with a cop (7) of 4.5 and (c) operate an electrical-resistance heater.
Answers: 3
You know the right answer?
Garden City is finalizing the design of an activated sludge WWTP and has the following design inform...
Questions
question
Mathematics, 21.02.2020 17:22
question
Mathematics, 21.02.2020 17:22
Questions on the website: 13722362