Determine the required reactor volume, in million gallons (MG), for a completely mixed, aerobic, activated sludge system which will treat 1 MGD of domestic wastewater. The waste water has an initial ultimate BOD of 200 mg/L. The effluent requirement is 10 mg/L of ultimate BOD. The first order degradation rate constant is K = 0.1 L/mg-day, i. e. the governing equation is q = KSe for calculating the specific substrate utilization rate (q) through kinetic parameters. Se is the effluent ultimate BOD (i. e. 10 mg/L). The mixed liquor volatile suspended solids (X) equals 3,000 mg/L. What is the reactor volume? a. 0.095 MG
b. 0.063 MG
c. 0.92 MG
d. 0.13 MG

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 19:10
What are the major differences between injection molding and extrusion?
Answers: 2
question
Engineering, 04.07.2019 19:10
Agas contained within a piston-cylinder assembly e end nation about same energy states, 1 and 2, where pi 10 bar, v undergoes two processes, a and b, between the sam 0.1 m3, ui-400 kj and p2 1 bar, v2 1.0 m2, u2 200 kj: process a: process from 1 to 2 during which the pressure- volume relation is pv constant process b: constant-volume process from state 1 to a pressure of 2 bar, followed by a linear pressure-volume process to +20 0 state 2 kinetic and potential energy effects can be ignored. for each of the processes a and b, (a) sketch the process on p-v coordinates, (b) evaluate the work, in kj, and (c) evaluate process the heat transfer, in kj
Answers: 2
question
Engineering, 04.07.2019 19:20
At steady state, air at 200 kpa, 325 k, and mass flow rate of 0.5 kg/s enters an insulated duct having differing inlet and exit cross-sectional areas. the inlet cross-sectional area is 6 cm2. at the duct exit, the pressure of the air is 100 kpa and the velocity is 250 m/s. neglecting potential energy effects and modeling air as an 1.008 kj/kg k, determine ideal gas with constant cp = (a) the velocity of the air at the inlet, in m/s. (b) the temperature of the air at the exit, in k. (c) the exit cross-sectional area, in cm2
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Determine the required reactor volume, in million gallons (MG), for a completely mixed, aerobic, act...
Questions
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
Mathematics, 15.12.2020 01:40
question
English, 15.12.2020 01:40
Questions on the website: 13722363